| Brand | OLYMPUS |
|---|---|
| Model | EG-2970K |
| Series | Insertion Tube |
| Moedl | GIF-Q260 |
| Application | Medical Equipment |
| Brand | Olympus |
|---|---|
| Model | BF-H290 |
| Series | Insert Tube |
| Packaging Details | Standard Package |
| Place of Origin | China |
| Brand | PENTAX |
|---|---|
| Model | EC-3890Li |
| Series | Insertion Tube |
| Packaging Details | Standard Package |
| Place of Origin | China |
| Brand | Olympus/ Pentax/ Fuji |
|---|---|
| Common Name | Air/Water Valve Tube (A/W Tube) |
| Condition | Compatible & New |
| Primary Function | Delivers Air For Insufflation And Water For Lens Cleaning. |
| Key Characteristic | Transparency (to Visually Confirm Patency And Flow). |
| Brand | Olympus |
|---|---|
| Model | MAJ-880 |
| Condition | Original & New |
| Product Type | Injection Tube / Flushing Tube / Cleaning Tube |
| Reusability | Yes |
| Brand | Olympus |
|---|---|
| Model | MH-946 |
| Condition | Brand New |
| Type | Injection Tube |
| Compatibility | Olympus EVIS/OES Series Flexible Endoscopes |
| Brand | Fujinon |
|---|---|
| Model | EG-590WR |
| Series | LIGHT GUIDE TUBE |
| Packaging Details | Standard Package |
| Place of Origin | China |
| Brand | FUJINON |
|---|---|
| Model | EG-530N |
| Fault | 1.Biopsy Tube Broken; 2.Angle Is Not Enough; 3.Camera Over-heating, There Are Occasional Snowflakes On The Image And Big Risk For CCD; 4.Insert Tube Aging And Wrinkle; 5.Light Guide Tube Aging And Wrinkle; 6.Stress Boot Of Light Guide Tube Broken; 7. |
| Solution | 1: Replace CCD; Insert Tube; Light Bundle; Biopsy Tube; Bending Mesh; Wires; Bending Section; Rubber; Light Guide Tube; Stress Boot; Eve Tube Solution 2: Replace Insert Tube, Light Bundle, Biopsy Tube, Bending Mesh And Wired, Coil Pipe, Rubber, Light Guid |
| Packaging Details | Standard Package |
| Brand | Olympus |
|---|---|
| Model | GIF-H170 |
| Fault | 1. The Top Left And Middle Right Side With Blur Image, Objective Lens Broken. 2. 20% Light Bundle Broken, The Small Lens Turned Yellow. 3. Insert Tube Yellow And Wrinkles. 4. The Biopsy Tube Abrasion. 5. The Wire And Helix Tube Abrasion. 6. Light Gu |
| Solution | Replace Objective Lens, Light Bundle, Small Lens, Insert Tube, Biopsy Tube, Wires, Helix Tube, Light Guide Tube And Rubber. |
| Packaging Details | Standard Package |
| Brand | Olympus |
|---|---|
| Model | GIF-1TQ160 |
| Fault | 1.With Image, But CCD With Broken. 2.Light Bundle Broken Completely. 3.Insert Tube Abrasion. 4. No Biopsy Tube. 5. No Air&water Tube, No Water Supply Tube. 6. No Bending Section Assembly. 7. No Digital Tip. |
| Solution | Replace CCD, Digital Tip, Light Bundle, Insert Tube,biopsy Tube, Air&water Tube, Water Supply Tube,bending Section,wires,helix Tube And Rubber. |
| Packaging Details | Standard Package |