| Brand | Olympus |
|---|---|
| Model | GIF-Q150 |
| Fault | 1. With Image; 2. Light Bundlebreak Badly; 3. Insert Tubeaging; 4. Biopsy Tubeabrasion, Leakage Badly; 5. Angle Tied, Bendingsection, Wires And Helix Tube Abrasion; 6. Rubberwithout Glue. |
| Solution | Replace Light Bundle, Insert Tube, Biopsy Tube, Bending Section, Wires, Helixtube And Rubber. (No Warranty For CCD) |
| Packaging Details | Standard Package |
| Training Courses | Cover Ultrasound Probes, Flexible And Rigid Endoscopes, Camera Systems, Camera Heads, Surgical Instruments, Dynamical Systems |
|---|---|
| Warranty | 90 Days |
| Repair Time | 7 Working Days |
| Repair Price | $**** |
| Training Team | Professional Team With Rich Maintenance Experience And Profound Theoretical Knowledge |
| Brand | Olympus |
|---|---|
| Model | CF-2T160L |
| Fault | 1. With Image. 2. 10% Light Bundle Broken. 3. Insert Tube Is Ok. 4. Biopsy Tube Abrasion. 5. Angle Tied, Bending Section Transformation. 6. Wires, Helix Tube Abrasion, No Up Angle. |
| Solution | Replace Wires, Helix Tube, Bending Section And Rubber. |
| Packaging Details | Standard Package |
| Brand | KARL STORZ |
|---|---|
| Model | 11278A1 |
| Fault | 1) Image Spotted With Partially Black Point, Image Bundle Aged 2) Light Bundle Partially Wire Broken 3) Insert Tube Aged 4) Biopsy Tube Abrasion And Leakage 5) Wires And Coil Pipe Abrasion |
| Solution | Replace HD Image Bundle, Light Bundle, Insert Tube, Wires, Coil Pipe And Rubber. |
| Packaging Details | Standard Package |
| Brand | Insighters |
|---|---|
| Model | IS3-F |
| Fault | 1. Image Blank Screen; 2. Insert Tube Abrasion 3. Bending Section Transformation; 4. Distal Head Transformation; |
| Solution | Replace CCD, Insert Tube, Bending Section, Rubber |
| Packaging Details | Standard Package |
| Brand | Olympus |
|---|---|
| Model | LTF-160 |
| Fault | 1.with Image, But Big Risk For CCD After Leakage. 2. Light Bundle Broken Completely. 3. Insert Tube With Little Scratch. 4. Biopsy Tube Abrasion And Leakage. 5. Wires And Helix Tube Abrasion. 6. Grip Broken, Leakage. 7. All The Buttons Failure. 8. R |
| Solution | Replace CCD,light Bundle, Biopsy Tube, Wires,helix Tube,grip And Rubber, Repair All The Buttons. |
| Packaging Details | Standard Package |
| Brand | R Wolf |
|---|---|
| Model | 7326071 |
| Fault | The Image Has Spots,image Bundle Aging,light Bundle Broken;Insert Tube Aging;Biopsy Channel Worn And Leakage;Bending Section,wire And Helix Tube Were Worn |
| Solution | Replace The Light Bundle,image Bundle,rubber,biopsy Channel,helix Tube,wire. |
| Packaging Details | Standard Package |
| Brand | Olympus |
|---|---|
| Model | CYF V2 |
| Fault | Leakage |
| Solution | Replace The Insert Tube, Light Bundle, Biopsy Channel, Bending Section, Wire, Steel Mesh, Rubber |
| Packaging Details | Standard Package |
| Brand | Olympus |
|---|---|
| Model | A70940A |
| Fault | 1. Image Blur, Black Dots And Dark. 2. Fiber Not Light Enough. 3. Rod Lens Broken. 4. Objective Lens Broken And Dirty. |
| Solution | 1. Replace Rod Lens. 2. Replace Inner Tube. 3. Replace Outer Tube. 4. Replace Objective Lens Group. 5. Clean The Eyepiece. 6. Replace Fiber. 7. Clean And Install The Optical Path, Check The Image. 8. Seal With Endoscope And Test. |
| Packaging Details | Standard Package |
| Brand | Olympus |
|---|---|
| Model | GIF-XQ240 |
| Fault | Leakage. |
| Solution | Replace Light Guide Tube,NO.1 Button,wire,mesh,adjust Angle. |
| Packaging Details | Standard Package |