logo
Found 90 products for "

medical device repair training

"
Quality Samsung Medison P2-4AH Cardiac probe for repair factory

Samsung Medison P2-4AH Cardiac probe for repair

Samsung Medison P2-4AH Cardiac probe for repair Brief Description Fault:Lens problem, crystal damage. Solution:Replace probe lens, replace crystal. Problem & Solutoin Brand Samsung Model P2-4AH Fault Lens problem, crystal damage Solution Replace probe lens, replace crystal Common issues with P2-4AH probe Image Dropout (Dead Elements) Cable Damage Connector Damage Acoustic Lens/Membrane Damage If your instrument has any of the above problems or others, please feel free to

Quality STORZ 13820pks Gastroscope for Repair factory

STORZ 13820pks Gastroscope for Repair

STORZ 13820pks Gastroscope for Repair Brief Description Fault: 1.Rubber leakage; 2.Wire abrasion; 3. no up angle, other angle lack of. Solution: 1. Replace the wires, coil pipe, rubber; 2.Adjust angle. Problem & Solutoin Brand STORZ Model 13820pks Fault 1.Rubber leakage; 2.Wire abrasion; 3. no up angle, other angle lack of Solution 1. Replace the wires, coil pipe, rubber; 2.Adjust angle Common issues with 13820pks Gastroscope Dim or Uneven Illumination Fuzzy, Blurry, or

Quality Olympus GIF-Q150 gastroscope for repair factory

Olympus GIF-Q150 gastroscope for repair

Olympus GIF-Q150 gastroscope for repair Brief Description Fault: 1.with image; 2.one eye of light bundle broken; 3.insert tube little aging; 4.biopsy tube abrasion; 5.bending section deformation; 6.wires and helix tube abrasion; 7.light guide tube aging and wrinkle. Solution: Replace light bundle ,insert tube, biopsy tube,bending section,wires,helix tube,light guide tube and rubber. Problem & Solutoin Brand OLYMPUS Model GIF-Q150 Fault 1.with image; 2.one eye of light

Quality Olympus TJF-160VR endoscope for repair factory

Olympus TJF-160VR endoscope for repair

Olympus TJF-160VR endoscope for repair Brief Description Fault: 1.No image, CCD broken. 2. Light bundle broken completely. 3. Insert tube aging and wrinkle. 4. Biopsy tube broken. 5. Wires and helix tube broken. 6. clamp wires broken. 7. Operation part broken, no angle. 8. Grip broken. 9. The scope be separated by someone before, some parts missing. Solution: Replace digital parts,CCD,light bundle,insert tube, biopsy tube,air&water tube, bending section, wires,helix tube,

Quality Olympus GIF-H180J gastroscope for repair factory

Olympus GIF-H180J gastroscope for repair

Olympus GIF-H180J gastroscope for repair Brief Description Fault: 1.image with shadow; 2.light bundle broken; 3.insert tube with bite mark; 4.biopsy tube abrasion; 5.bending section serious deformation; 6.wires and helix tube abrasion; 7.light guide tube aging and wrinkle. Solution: Replace CCD, light bundle, insert tube,biopsy tube,aire&water tube,bending section,wires,helix tube,light guide tube and rubber. Problem & Solutoin Brand Olympus Model GIF-H180J Fault 1.image

Quality Olympus BF-XP160F Bronchoscope for repair factory

Olympus BF-XP160F Bronchoscope for repair

Olympus BF-XP160F fiber scope for repair Brief Description Fault: 1. Image degumming, serious color, CCD aging, a few black and gray spots; 2. 20% of the light bundle is broken; 3. Insert tube aging slightly; 4. Biopsy tube wear, not smooth; 5. Bending section, steel wire, screw tube wear; Solution: Replace CCD, image beam, beam, insert tube, pliers tube, snake bone, steel wire, spiral tube, rubber. Problem & Solutoin Brand Olympus Model BF-XP160F Fault 1. Image degumming,

Quality KARL STORZ 11278A1 ureteroscope for repair factory

KARL STORZ 11278A1 ureteroscope for repair

KARL STORZ 11278A1 ureteroscope for repair Brief Description Fault: 1) Image spotted with partially black point, image bundle aged 2) Light bundle partially wire broken 3) Insert tube aged 4) Biopsy tube abrasion and leakage 5) Wires and coil pipe abrasion Solution: Replace HD image bundle, light bundle, insert tube, wires, coil pipe and rubber. Problem & Solutoin Brand KARL STORZ Model 11278A1 Fault 1) Image spotted with partially black point, image bundle aged 2) Light

Quality Insighters IS3-F laryngoscope for repair factory

Insighters IS3-F laryngoscope for repair

Insighters IS3-F laryngoscope for repair Brief Description Fault: 1. Image blank screen; 2. Insert tube abrasion 3. Bending section transformation; 4. Distal head transformation; Solution: Replace CCD, insert tube, bending section, rubber Problem & Solutoin Brand Insighters Model IS3-F Fault 1. Image blank screen; 2. Insert tube abrasion 3. Bending section transformation; 4. Distal head transformation; Solution Replace CCD, insert tube, bending section, rubber Common

Quality Olympus GIF-Q150 Gastroscope for repair factory

Olympus GIF-Q150 Gastroscope for repair

Olympus GIF-Q150 Gastroscope for repair Brief Description Fault: 1. With image; 2. Light bundlebreak badly 3. Insert tubeaging; 4. Biopsy tubeabrasion, leakage badly; 5. Angle tied, bendingsection, wires and helix tube abrasion; 6. Rubberwithout glue. Solution: Replace light bundle, insert tube, biopsy tube, bending section, wires, helixtube and rubber. (No warranty for CCD) Problem & Solutoin Brand Olympus Model GIF-Q150 Fault 1. With image; 2. Light bundlebreak badly 3