Quality 1898200T M4 Straightshot Microdebrider and Handpiece for repair factory

1898200T M4 Straightshot Microdebrider and Handpiece for repair

1898200T M4 Straightshot Microdebrider and Handpiece for repair ► Brief Description Fault: 1) The bearing is corroded and the seal is broken. 2) Motor stuck, inside is full of disinfection residue, motor corrosion. 3) The rotation direction of the knife head is stuck. 4) Handle paint off, internal ...

Quality GE RIC6-12-D endocavity probe for repair factory

GE RIC6-12-D endocavity probe for repair

GE RIC6-12-D endocavity probe for repair ► Brief Description Fault: Lens problem. Solution: Replace lens,Clean cable. ►Problem & Solutoin BrandGEModelRIC6-12-DFaultLens problemSolutionReplace lens,Clean cable ► Common issues with RIC6-12-D Probe Dome Damage and Fluid LeaksImage Dropouts (Dead ...

Quality Karl Storz 27005BA endoscope for repair factory

Karl Storz 27005BA endoscope for repair

Karl Storz 27005BA endoscope for repair ► Brief Description Fault: 1. No image. 2. Fiber abrasion. 3. Rod lens broken and cracked. 4. Objective lens broken and dirty. 5. Eyepiece cover broken. Solution: 1. Replace rod lens. 2. Replace inner tube. 3. Replace outer tube. 4. Replace objective lens ...

Quality OLYMPUS TJF-Q180V DUODENOSCOPE FOR REPAIR factory

OLYMPUS TJF-Q180V DUODENOSCOPE FOR REPAIR

OLYMPUS TJF-Q180V DUODENOSCOPE FOR REPAIR ► Brief Description Fault: 1. Image ok; 2. Light bundlestill ok; 3. Insert tubestill ok; 4. Biopsy tubewear; 5. Bendingsection, wires and helix tube wear; 6. Knob leakage. Solution: Suggest toreplace biopsy tube, bending section, wires, helix tube, knob and ...

Quality L15-7io Linear probe for repair factory

L15-7io Linear probe for repair

L15-7io Linear probe for repair ► Brief Description Fault: Lens problem. Solution: Replace probe lens. ►Problem & Solutoin Model L15-7io Fault Lens problem Solution Replace probe lens ► Common issues with L15-7io probe Cable and Connector Issues Acoustic Lens Damage Crystal/Element Failure Housing...

Quality Olympus ENF-GP fiber nasopharyngeal laryngoscope for repair factory

Olympus ENF-GP fiber nasopharyngeal laryngoscope for repair

Olympus ENF-GP fiber nasopharyngeal laryngoscope for repair ► Brief Description Fault: 1. Image with black point and image bundle broken 2. Light bundle aged 3. Insert tube aging and wrinkle 4. Bending section deformation 5. Angle with not enough 6. Rubber abrasion Solution: Replace image bundle; ...

Quality OLYMPUS TJF-Q180V Electronic Duodenoscope For Repair factory

OLYMPUS TJF-Q180V Electronic Duodenoscope For Repair

OLYMPUS TJF-Q180V Electronic Duodenoscope For Repair ► Brief Description Inspection Results: 1. Image display is available; 2. The light bundle brightness is acceptable; 3. The insertion tube is worn; 4. The light guide tube is worn; 5. The angle is insufficient, the snake bone, steel wire and helix ...

Quality Toshiba PST-25BT Phased Array Probe For Repair factory

Toshiba PST-25BT Phased Array Probe For Repair

Toshiba PST-25BT Phased Array Probe For Repair ► Brief Description Fault: Housing break, image weak, crystal aging. Solution: Replace crystal and housing. ►Problem & Solutoin Brand Toshiba Model PST-25BT Fault Housing break, image weak, crystal aging Solution Replace crystal and housing ► Common ...

Quality T-D0022 Medical Drill Repair Tool For SYNTHES 530.610 Battery Operated Reciprocator Drill factory

T-D0022 Medical Drill Repair Tool For SYNTHES 530.610 Battery Operated Reciprocator Drill

Product Description 1. Introduction T-D0022 Repair tool for SYNTHES 530.610 Battery Operated Reciprocator Drill Brand-new Perfectly repair drill without scratch 2. Characteristics and Advantages Number:T-D0022 Features: Durable, Portable, Multi-functional Advantages: High Quality Materials, Precise ...