Quality Olympus A70940A  Autoclavable Arthroscope for repair factory

Olympus A70940A Autoclavable Arthroscope for repair

Olympus A70940A Autoclavable Arthroscope for repair Brief Description Fault: 1. Image blur, black dots and dark. 2. Fiber not light enough. 3. Rod lens broken. 4. Objective lens broken and dirty. Solution: 1. Replace rod lens. 2. Replace inner tube. 3. Replace outer tube. 4. Replace objective lens group. 5. Clean the eyepiece. 6. Replace fiber. 7. Clean and install the optical path, check the image. 8. Seal with endoscope and test. Problem & Solutoin Brand Olympus Model

Quality GE 4D3C-L 4D Convex Transducer For Repair factory

GE 4D3C-L 4D Convex Transducer For Repair

GE 4D3C-L 4D Convex Transducer For Repair Brief Description Fault: 1.Probe dome abrasion & leakage, 2. Dome tube damaged, 3. 4D function not work, 4. Electric motor damaged. Solution:Replace the dome, dome tube; repair electric motor. Problem & Solutoin BrandGEModel4D3C-LFault1.Probe dome abrasion & leakage, 2. Dome tube damaged, 3. 4D function not work, 4. Electric motor damaged.SolutionReplace the dome, dome tube; repair electric motor Common issues with 4D3C-L 4D

Quality Olympus LTF-160 thoracoscope for repair factory

Olympus LTF-160 thoracoscope for repair

Olympus LTF-160 thoracoscope for repair Brief Description Fault: 1.with image, but big risk for CCD after leakage. 2. Light bundle broken completely. 3. Insert tube with little scratch. 4. Biopsy tube abrasion and leakage. 5. Wires and helix tube abrasion. 6. Grip broken, leakage. 7. All the buttons failure. 8. Rubber leakage. 9. the whole scope leakage. Solution: Replace CCD,light bundle, biopsy tube, wires,helix tube,grip and rubber, repair all the buttons. Problem &

Quality CCD Driver Board for Olympus GIF-H170 Endoscope factory

CCD Driver Board for Olympus GIF-H170 Endoscope

CCD driver board for Olympus GIF-H170 Endoscop Brief Description The CCD driver board is a critical component in the Olympus GIF-H170 endoscope, responsible for controlling the charge-coupled device (CCD) that captures images during endoscopic procedures . Features Compatibility : Specifically designed for the Olympus GIF-H170 video gastroscope Function : Controls the CCD sensor that provides high-resolution imaging Signal Processing : Handles video signal transmission

Quality Olympus TJF-160VR endoscope for repair factory

Olympus TJF-160VR endoscope for repair

Olympus TJF-160VR endoscope for repair Brief Description Fault: 1.No image, CCD broken. 2. Light bundle broken completely. 3. Insert tube aging and wrinkle. 4. Biopsy tube broken. 5. Wires and helix tube broken. 6. clamp wires broken. 7. Operation part broken, no angle. 8. Grip broken. 9. The scope be separated by someone before, some parts missing. Solution: Replace digital parts,CCD,light bundle,insert tube, biopsy tube,air&water tube, bending section, wires,helix tube,

Quality R Wolf 7326071 ureteroscope for repair factory

R Wolf 7326071 ureteroscope for repair

R Wolf 7326071 ureteroscope for repair Brief Description Fault: The image has spots,image bundle aging,light bundle broken;Insert tube aging;Biopsy channel worn and leakage;Bending section,wire and helix tube were worn. Solution: Replace the light bundle,image bundle,rubber,biopsy channel,helix tube,wire. Problem & Solutoin Brand R Wolf Model 7326071 Fault The image has spots,image bundle aging,light bundle broken;Insert tube aging; Biopsy channel worn and leakage;Bending

Quality Aloka UST-5413 linear array ultrasound probe for repair factory

Aloka UST-5413 linear array ultrasound probe for repair

Aloka UST-5413 linear array ultrasound probe for repair Brief Description Fault: Lens break. Solution: Replace lens. Problem & Solutoin BrandAlokaModelUST-5413FaultLens breakSolutionReplace lens Common issues with UST-5413 Probe Image dropouts or black linesAcoustic lens damageCable damageConnector damageWeak or noisy image FAQ How can we prevent the acoustic lens on the UST-5413 from peeling after a repair? Avoid Solvent Cleaners: Never use solutions containing high

Quality STORZ 13820pks Gastroscope for Repair factory

STORZ 13820pks Gastroscope for Repair

STORZ 13820pks Gastroscope for Repair Brief Description Fault: 1.Rubber leakage; 2.Wire abrasion; 3. no up angle, other angle lack of. Solution: 1. Replace the wires, coil pipe, rubber; 2.Adjust angle. Problem & Solutoin Brand STORZ Model 13820pks Fault 1.Rubber leakage; 2.Wire abrasion; 3. no up angle, other angle lack of Solution 1. Replace the wires, coil pipe, rubber; 2.Adjust angle Common issues with 13820pks Gastroscope Dim or Uneven Illumination Fuzzy, Blurry, or

Quality Olympus GIF-Q150 gastroscope for repair factory

Olympus GIF-Q150 gastroscope for repair

Olympus GIF-Q150 gastroscope for repair Brief Description Fault: 1.with image; 2.one eye of light bundle broken; 3.insert tube little aging; 4.biopsy tube abrasion; 5.bending section deformation; 6.wires and helix tube abrasion; 7.light guide tube aging and wrinkle. Solution: Replace light bundle ,insert tube, biopsy tube,bending section,wires,helix tube,light guide tube and rubber. Problem & Solutoin Brand OLYMPUS Model GIF-Q150 Fault 1.with image; 2.one eye of light