| Size | Various Sizes Available |
|---|---|
| Material | Stainless Steel |
| Efficiency | Efficient Repair Process |
| Function | Repairing And Maintaining Flexible Endoscopes |
| Package | Individual Or Bulk Packaging Available |
| Brand | Karl Storz |
|---|---|
| Model | 27005BA |
| Fault | 1. No Image. 2. Fiber Abrasion. 3. Rod Lens Broken And Cracked. 4. Objective Lens Broken And Dirty. 5. Eyepiece Cover Broken. |
| Solution | 1. Replace Rod Lens. 2. Replace Inner Tube. 3. Replace Outer Tube. 4. Replace Objective Lens Group. 5. Clean The Eyepiece. 6. Replace Fiber. 7. Replace Eyepiece Cover. 8. Clean And Install The Optical Path, Check The Image. 9. Seal With Endoscope A |
| Packaging Details | Standard Package |
| Brand | Karl Storz |
|---|---|
| Model | 27005BA |
| Fault | 1. No Image. 2. Fiber Abrasion. 3. Rod Lens Broken And Cracked. 4. Objective Lens Broken And Dirty. 5. Eyepiece Cover Broken. |
| Solution | 1. Replace Rod Lens. 2. Replace Inner Tube. 3. Replace Outer Tube. 4. Replace Objective Lens Group. 5. Clean The Eyepiece. 6. Replace Fiber. 7. Replace Eyepiece Cover. 8. Clean And Install The Optical Path, Check The Image. 9. Seal With Endoscope A |
| Packaging Details | Standard Package |
| Brand | Philips |
|---|---|
| Model | C5-2 |
| Fault | Strain Relief Damage, Cable Broken |
| Solution | Replace Strain Relief, Repair Cable. |
| Packaging Details | Standard Package |
| Brand | GE |
|---|---|
| Model | 4C-RS |
| Fault | Lens Broken, Cable Broken, Crystal Bad |
| Solution | Replace Probe Head, Repair Cable |
| Packaging Details | Standard Package |
| Brand | Philips |
|---|---|
| Model | S5-2 |
| Fault | Lens Problem, Cable Broken, Without Strain Relief |
| Solution | Replace Probe Lens, Repair Cable, Replace Strain Relief |
| Packaging Details | Standard Package |
| Brand | OLYMPUS |
|---|---|
| Model | CF-H290I |
| Series | CCD OBJECTIVE LENS |
| Packaging Details | Standard Package |
| Place of Origin | China |
| Brand | Olympus |
|---|---|
| Model | BW-20T |
| Series | Gastroscope |
| Condition | Brand-new |
| Type | Reusable Channel Cleaning Brush |
| Brand | Olympus |
|---|---|
| Model | MAJ-210 |
| Series | SINGLE USE |
| Condition | Original & New |
| Type | Sterile Biopsy Valve |
| Brand | Olympus |
|---|---|
| Model | ENF-GP |
| Fault | 1. Image With Black Point And Image Bundle Broken 2. Light Bundle Aged 3. Insert Tube Aging And Wrinkle 4. Bending Section Deformation 5. Angle With Not Enough 6. Rubber Abrasion |
| Solution | Replace Image Bundle; Light Bundle; Insert Tube; Wires; Helix Tube; Bending Section; Rubber |
| Packaging Details | Standard Package |