| Brand | Insighters |
|---|---|
| Model | IS3-F |
| Fault | 1. Image Blank Screen; 2. Insert Tube Abrasion 3. Bending Section Transformation; 4. Distal Head Transformation; |
| Solution | Replace CCD, Insert Tube, Bending Section, Rubber |
| Packaging Details | Standard Package |
| Brand | R Wolf |
|---|---|
| Model | 7326071 |
| Fault | The Image Has Spots,image Bundle Aging,light Bundle Broken;Insert Tube Aging;Biopsy Channel Worn And Leakage;Bending Section,wire And Helix Tube Were Worn |
| Solution | Replace The Light Bundle,image Bundle,rubber,biopsy Channel,helix Tube,wire. |
| Packaging Details | Standard Package |
| Brand | Olympus |
|---|---|
| Model | CF-240AI |
| Fault | Image Blur,insert Tube Aging,light Guide Squashed,light Guide Broken 50%,nozzle Blocked,angle Tight,forceps Channel Aging. |
| Solution | Replace Insertion Tube,CCD Chips,light Guide,forceps Channel,water Channel,angulation Wire,bending Mesh,spiral Tube,light Guide Tube,bending Rubber. |
| Packaging Details | Standard Package |
| Brand | Olympus |
|---|---|
| Model | CYF V2 |
| Fault | Leakage |
| Solution | Replace The Insert Tube, Light Bundle, Biopsy Channel, Bending Section, Wire, Steel Mesh, Rubber |
| Packaging Details | Standard Package |
| Brand | Olympus |
|---|---|
| Model | GIF-XQ240 |
| Fault | Leakage. |
| Solution | Replace Light Guide Tube,NO.1 Button,wire,mesh,adjust Angle. |
| Packaging Details | Standard Package |
| Brand | Olympus |
|---|---|
| Model | GIF-Q150 |
| Fault | 1. With Image; 2. Light Bundlebreak Badly; 3. Insert Tubeaging; 4. Biopsy Tubeabrasion, Leakage Badly; 5. Angle Tied, Bendingsection, Wires And Helix Tube Abrasion; 6. Rubberwithout Glue. |
| Solution | Replace Light Bundle, Insert Tube, Biopsy Tube, Bending Section, Wires, Helixtube And Rubber. (No Warranty For CCD) |
| Packaging Details | Standard Package |
| Brand | Olympus |
|---|---|
| Model | A70940A |
| Fault | 1. Image Blur, Black Dots And Dark. 2. Fiber Not Light Enough. 3. Rod Lens Broken. 4. Objective Lens Broken And Dirty. |
| Solution | 1. Replace Rod Lens. 2. Replace Inner Tube. 3. Replace Outer Tube. 4. Replace Objective Lens Group. 5. Clean The Eyepiece. 6. Replace Fiber. 7. Clean And Install The Optical Path, Check The Image. 8. Seal With Endoscope And Test. |
| Packaging Details | Standard Package |
| Brand | Olympus |
|---|---|
| Model | A4674A |
| Fault | 1. Image Blur And Black Shadow. 2. Rod Lens Broken. 3. Outer Tube Bending And Transformation. |
| Solution | 1. Replace Rod Lens. 2. Replace Inner Tube. 3. Replace Outer Tube. 4. Replace Objective Lens Group. 5. Clean The Eyepiece. 6. Replace Fiber. 7. Clean And Install The Optical Path, Check The Image. 8. Seal With Endoscope And Test. |
| Packaging Details | Standard Package |
| Brand | Karl Storz |
|---|---|
| Model | 27005BA |
| Fault | 1. No Image. 2. Fiber Abrasion. 3. Rod Lens Broken And Cracked. 4. Objective Lens Broken And Dirty. 5. Eyepiece Cover Broken. |
| Solution | 1. Replace Rod Lens. 2. Replace Inner Tube. 3. Replace Outer Tube. 4. Replace Objective Lens Group. 5. Clean The Eyepiece. 6. Replace Fiber. 7. Replace Eyepiece Cover. 8. Clean And Install The Optical Path, Check The Image. 9. Seal With Endoscope A |
| Packaging Details | Standard Package |
| Brand | Philips |
|---|---|
| Model | L12-5 |
| Series | Crystal |
| Condition | Compatible & New |
| Brand Name | Careutech |