| Brand | Olympus |
|---|---|
| Model | LTF-160 |
| Fault | 1.with Image, But Big Risk For CCD After Leakage. 2. Light Bundle Broken Completely. 3. Insert Tube With Little Scratch. 4. Biopsy Tube Abrasion And Leakage. 5. Wires And Helix Tube Abrasion. 6. Grip Broken, Leakage. 7. All The Buttons Failure. 8. R |
| Solution | Replace CCD,light Bundle, Biopsy Tube, Wires,helix Tube,grip And Rubber, Repair All The Buttons. |
| Packaging Details | Standard Package |
| Brand | Olympus |
|---|---|
| Model | CF-Q160AL |
| Fault | 1.No Image, CCD Broken; 2.image Broken Completely; 3.insert Tube Aging; 4.biopsy Tube Abrasion; 5.bending Section Abrasion; 6.wires And Helix Tube Abrasion; 7.light Guide Tube Aging And Wrinkle. |
| Solution | Replace CCD, Light Bundle, Insert Tube,biopsy Tube,aire&water Tube,bending Section,wires,helix Tube,light Guide Tube,all The Fstener Part,clamp And Rubber. |
| Packaging Details | Standard Package |
| Brand | Stryker |
|---|---|
| Model | 0502-503-030 |
| Fault | Image Blur, Objective Lens Loose Without Glue, Inner Optical Parts Broken. |
| Solution | Add Glue For Objective Lens, Replace Inner Optical Parts, Clean And Adjust Optical System, Seal With Eyepiece. |
| Packaging Details | Standard Package |
| Brand | GE |
|---|---|
| Model | 4D3C-L |
| Fault | 1.Probe Dome Abrasion & Leakage, 2. Dome Tube Damaged, 3. 4D Function Not Work, 4. Electric Motor Damaged. |
| Solution | Replace The Dome, Dome Tube; Repair Electric Motor |
| Packaging Details | Standard Package |
| Brand | GE |
|---|---|
| Model | 4C-RS |
| Fault | Lens Broken, Cable Broken, Crystal Bad |
| Solution | Replace Probe Head, Repair Cable |
| Packaging Details | Standard Package |
| Brand | KARL STORZ |
|---|---|
| Model | TIPCAM 1S 3D |
| Condition | Brand New |
| Serise | Video Cable |
| Data Type | Dual-stream Full HD Digital Video Data |
| Brand | Olympus |
|---|---|
| Model | OTV-S6H-1D |
| Fault | Cable Aging And Interference |
| Solution | Replace Cable |
| Packaging Details | Standard Package |
| Brand | Olympus |
|---|---|
| Model | ENF-GP |
| Fault | 1. Image With Black Point And Image Bundle Broken 2. Light Bundle Aged 3. Insert Tube Aging And Wrinkle 4. Bending Section Deformation 5. Angle With Not Enough 6. Rubber Abrasion |
| Solution | Replace Image Bundle; Light Bundle; Insert Tube; Wires; Helix Tube; Bending Section; Rubber |
| Packaging Details | Standard Package |
| Brand | OLYMPUS |
|---|---|
| Model | CF-H190L |
| Series | BENDING SECTION WITH STOPPER |
| Packaging Details | Standard Package |
| Place of Origin | China |
| Brand | TOSHIBA |
|---|---|
| Model | PA240 |
| Series | Probe Lens |
| Probe Lens | Compatible & New |
| Brand Name | TOSHIBA |