| Brand | Toshiba |
|---|---|
| Model | PST-25BT |
| Fault | Housing Break, Image Weak, Crystal Aging |
| Solution | Replace Crystal And Housing |
| Packaging Details | Standard Package |
| Brand | Sonoscape |
|---|---|
| Model | C362 |
| Fault | Cystal Problem |
| Solution | Replace The Crystal |
| Packaging Details | Standard Package |
| Brand | Medtronic |
|---|---|
| Model | 1898200T |
| Fault | 1) The Bearing Is Corroded And The Seal Is Broken. 2) Motor Stuck, Inside Is Full Of Disinfection Residue, Motor Corrosion. 3) The Rotation Direction Of The Knife Head Is Stuck. 4) Handle Paint Off, Internal Corrosion. |
| Solution | Exchange The Whole Handpiece Except Cable. |
| Packaging Details | Standard Package |
| Brand | GE |
|---|---|
| Model | RIC6-12-D |
| Fault | Lens Problem |
| Solution | Replace Lens,Clean Cable |
| Packaging Details | Standard Package |
| Brand | OLYMPUS |
|---|---|
| Model | TJF-Q180V |
| Fault | 1. Image Ok; 2. Light Bundlestill Ok; 3. Insert Tubestill Ok; 4. Biopsy Tubewear; 5. Bendingsection, Wires And Helix Tube Wear; 6. Knob Leakage. |
| Solution | Suggest Toreplace Biopsy Tube, Bending Section, Wires, Helix Tube, Knob And Rubber. (Nowarranty For CCD) |
| Packaging Details | Standard Package |
| Brand | Philips |
|---|---|
| Model | L15-7io |
| Fault | Lens Problem |
| Solution | Replace Probe Lens |
| Packaging Details | Standard Package |
| Brand | Olympus |
|---|---|
| Model | A70940A |
| Fault | 1. Image Blur, Black Dots And Dark. 2. Fiber Not Light Enough. 3. Rod Lens Broken. 4. Objective Lens Broken And Dirty. |
| Solution | 1. Replace Rod Lens. 2. Replace Inner Tube. 3. Replace Outer Tube. 4. Replace Objective Lens Group. 5. Clean The Eyepiece. 6. Replace Fiber. 7. Clean And Install The Optical Path, Check The Image. 8. Seal With Endoscope And Test. |
| Packaging Details | Standard Package |
| Brand | GE |
|---|---|
| Model | 4D3C-L |
| Fault | 1.Probe Dome Abrasion & Leakage, 2. Dome Tube Damaged, 3. 4D Function Not Work, 4. Electric Motor Damaged. |
| Solution | Replace The Dome, Dome Tube; Repair Electric Motor |
| Packaging Details | Standard Package |
| Brand | Olympus |
|---|---|
| Model | LTF-160 |
| Fault | 1.with Image, But Big Risk For CCD After Leakage. 2. Light Bundle Broken Completely. 3. Insert Tube With Little Scratch. 4. Biopsy Tube Abrasion And Leakage. 5. Wires And Helix Tube Abrasion. 6. Grip Broken, Leakage. 7. All The Buttons Failure. 8. R |
| Solution | Replace CCD,light Bundle, Biopsy Tube, Wires,helix Tube,grip And Rubber, Repair All The Buttons. |
| Packaging Details | Standard Package |
| Brand | Olympus |
|---|---|
| Model | GIF-H170 |
| Series | CCD Driver Board |
| Condition | Original |
| MOQ | 1 Piece |