| Brand | Olympus |
|---|---|
| Model | MAJ-1444 |
| Condition | Original & New |
| Type | Air/Water Valve |
| Compatibility | Olympus Ultrasonic Endoscopes |
| Brand | PENTAX |
|---|---|
| Model | EPK-i7000 |
| Product | Processor |
| Fault | It Cannot Recognize The Endoscope And Reports An Error. |
| Solution | Repair The System Board. |
| Brand | Olympus |
|---|---|
| Model | A70940A |
| Fault | 1. Image Blur, Black Dots And Dark. 2. Fiber Not Light Enough. 3. Rod Lens Broken. 4. Objective Lens Broken And Dirty. |
| Solution | 1. Replace Rod Lens. 2. Replace Inner Tube. 3. Replace Outer Tube. 4. Replace Objective Lens Group. 5. Clean The Eyepiece. 6. Replace Fiber. 7. Clean And Install The Optical Path, Check The Image. 8. Seal With Endoscope And Test. |
| Packaging Details | Standard Package |
| Brand | Olympus |
|---|---|
| Model | A4674A |
| Fault | 1. Image Blur And Black Shadow. 2. Rod Lens Broken. 3. Outer Tube Bending And Transformation. |
| Solution | 1. Replace Rod Lens. 2. Replace Inner Tube. 3. Replace Outer Tube. 4. Replace Objective Lens Group. 5. Clean The Eyepiece. 6. Replace Fiber. 7. Clean And Install The Optical Path, Check The Image. 8. Seal With Endoscope And Test. |
| Packaging Details | Standard Package |
| Brand | Karl Storz |
|---|---|
| Model | 27005BA |
| Fault | 1. No Image. 2. Fiber Abrasion. 3. Rod Lens Broken And Cracked. 4. Objective Lens Broken And Dirty. 5. Eyepiece Cover Broken. |
| Solution | 1. Replace Rod Lens. 2. Replace Inner Tube. 3. Replace Outer Tube. 4. Replace Objective Lens Group. 5. Clean The Eyepiece. 6. Replace Fiber. 7. Replace Eyepiece Cover. 8. Clean And Install The Optical Path, Check The Image. 9. Seal With Endoscope A |
| Packaging Details | Standard Package |
| Training Courses | Cover Ultrasound Probes, Flexible And Rigid Endoscopes, Camera Systems, Camera Heads, Surgical Instruments, Dynamical Systems |
|---|---|
| Warranty | 90 Days |
| Repair Time | 7 Working Days |
| Repair Price | $**** |
| Training Team | Professional Team With Rich Maintenance Experience And Profound Theoretical Knowledge |
| Brand | Stryker |
|---|---|
| Model | 0502-503-030 |
| SN | 103**** |
| Condition | Repaired |
| Brand Name | Stryker |
| Brand | GE |
|---|---|
| Model | RIC5-9-D |
| SN | 1870***** |
| Condition | Repaired |
| Brand Name | GE |
| Brand | LINVATEC |
|---|---|
| Model | HD4300 |
| SN | 62**** |
| Condition | Repaired |
| Brand Name | LINVATEC |
| Packaging Details | Standard Package |
|---|---|
| Place of Origin | China |
| Brand Name | Careutech |
| Model Number | OLYMPUS CF-HQ190L repair |