Quality Medical Device Repair Cases Stryker 30º 0502-503-030 Laproscope For Repair factory

Medical Device Repair Cases Stryker 30º 0502-503-030 Laproscope For Repair

Stryker 30º 0502-503-030 laproscope, SN:103**** Fault: Image blur, objective lens loose without glue, inner optical parts broken. Solution: Add glue for objective lens, replace inner optical parts, clean and adjust optical system, seal with eyepiece. Repair cost: $*** Common Issues with the Stryker ...

Quality STORZ 1HD H3-ZA 22220061 Autoclavable Camera Head TH104 Cable factory

STORZ 1HD H3-ZA 22220061 Autoclavable Camera Head TH104 Cable

Storz 1HD H3-ZA 22220061 / TH104 Autoclavable Camera Cable Brand: Storz Model: H3-ZA 22220061 Series: Camera Cable Use for Karl Storz Image 1 Spies HD Camera Head H3-ZA TH104 TH-104 If you have any questions about 1HD H3-ZA Autoclavable Camera Cable 22220061 for Storz, please feel free to contact us...

Quality Medical Device Repair Cases OF GE RIC5-9-D ULTRASOUND PROBE FOR REPAIR factory

Medical Device Repair Cases OF GE RIC5-9-D ULTRASOUND PROBE FOR REPAIR

GE RIC5-9-D Probe Fault: Dome loose, straight relief tiny broken, with error on machine. Solution: Replace dome and oiling. Repair cost : $***. Common Issues with the GE RIC5-9-D Ultrasound Probe: Image Artifacts/Dropouts: These can manifest as lines, shadowing, or a complete loss of image in ...

Quality OLYMPUS CF-HQ190L Medical Device Repair Cases Repair Tool Case factory

OLYMPUS CF-HQ190L Medical Device Repair Cases Repair Tool Case

OLYMPUS CF-HQ190L Repair Problem: 1, Image display;2, Light bundle broken about 10%;3, Insertion tube is ok;4, Biospy channel worn and leaking;5, The upper angle broken, helix tube and bending section were worn;6, Light guide tube indented and the back cover is leaking;7, The EL-connector is not ...

Quality PENTAX Medical EPK-i7000 Video Processor For Repair factory

PENTAX Medical EPK-i7000 Video Processor For Repair

PENTAX Medical EPK-i7000 Video Processor For Repair ► Brief Description Brand: PENTAX (PENTAX Endoscope Processor) Model: EPK-i7000 Serial Number: AC*** Fault: It cannot recognize the endoscope and reports an error. Solution: Repair the system board. Repair Time: 3-5 working days. Warranty Period: ...

Quality Olympus LTF-160 thoracoscope for repair factory

Olympus LTF-160 thoracoscope for repair

Olympus LTF-160 thoracoscope for repair ► Brief Description Fault: 1.with image, but big risk for CCD after leakage. 2. Light bundle broken completely. 3. Insert tube with little scratch. 4. Biopsy tube abrasion and leakage. 5. Wires and helix tube abrasion. 6. Grip broken, leakage. 7. All the ...

Quality OLYMPUS CF-H180AL Electronic Colonoscope For Repair factory

OLYMPUS CF-H180AL Electronic Colonoscope For Repair

OLYMPUS CF-H180AL Electronic Colonoscope For Repair ► Brief Description Inspection Results: 1. The image is dark, and the CCD is aged. 2. One branch of the light beam is disconnected. 3. The insertion tube is aged and wrinkled. 4. The lower angle is malfunctioning, the other angles are tight, and ...

Quality GE 4D3C-L 4D Convex Transducer For Repair factory

GE 4D3C-L 4D Convex Transducer For Repair

GE 4D3C-L 4D Convex Transducer For Repair ► Brief Description Fault: 1.Probe dome abrasion & leakage, 2. Dome tube damaged, 3. 4D function not work, 4. Electric motor damaged. Solution:Replace the dome, dome tube; repair electric motor. ►Problem & Solutoin BrandGEModel4D3C-LFault1.Probe dome ...

Quality GE 4C-RS abdominal probe for repair factory

GE 4C-RS abdominal probe for repair

GE 4C-RS abdominal probe for repair ► Brief Description Fault: Lens broken, cable broken, crystal bad. Solution: Replace probe head, repair cable. ►Problem & Solutoin Bran GE Model 4C-RS Fault Lens broken, cable broken, crystal bad Solution Replace probe head, repair cable ► Common issues with 4C-RS ...