| Brand | Insighters |
|---|---|
| Model | IS3-F |
| Fault | 1. Image Blank Screen; 2. Insert Tube Abrasion 3. Bending Section Transformation; 4. Distal Head Transformation; |
| Solution | Replace CCD, Insert Tube, Bending Section, Rubber |
| Packaging Details | Standard Package |
| Brand | KARL STORZ |
|---|---|
| Model | 11278A1 |
| Fault | 1) Image Spotted With Partially Black Point, Image Bundle Aged 2) Light Bundle Partially Wire Broken 3) Insert Tube Aged 4) Biopsy Tube Abrasion And Leakage 5) Wires And Coil Pipe Abrasion |
| Solution | Replace HD Image Bundle, Light Bundle, Insert Tube, Wires, Coil Pipe And Rubber. |
| Packaging Details | Standard Package |
| Brand | Olympus |
|---|---|
| Model | ENF-GP |
| Fault | 1. Image With Black Point And Image Bundle Broken 2. Light Bundle Aged 3. Insert Tube Aging And Wrinkle 4. Bending Section Deformation 5. Angle With Not Enough 6. Rubber Abrasion |
| Solution | Replace Image Bundle; Light Bundle; Insert Tube; Wires; Helix Tube; Bending Section; Rubber |
| Packaging Details | Standard Package |
| Brand | Olympus |
|---|---|
| Model | BF-XP160F |
| Fault | 1. Image Degumming, Serious Color, CCD Aging, A Few Black And Gray Spots; 2. 20% Of The Light Bundle Is Broken; 3. Insert Tube Aging Slightly; 4. Biopsy Tube Wear, Not Smooth; 5. Bending Section, Steel Wire, Screw Tube Wear; |
| Solution | Replace CCD, Image Beam, Beam, Insert Tube, Pliers Tube, Snake Bone, Steel Wire, Spiral Tube, Rubber. |
| Packaging Details | Standard Package |
| Brand | Olympus |
|---|---|
| Model | CF-2T160L |
| Fault | 1. With Image. 2. 10% Light Bundle Broken. 3. Insert Tube Is Ok. 4. Biopsy Tube Abrasion. 5. Angle Tied, Bending Section Transformation. 6. Wires, Helix Tube Abrasion, No Up Angle. |
| Solution | Replace Wires, Helix Tube, Bending Section And Rubber. |
| Packaging Details | Standard Package |
| Brand | Olympus |
|---|---|
| Model | CF-Q160AL |
| Fault | 1.No Image, CCD Broken; 2.image Broken Completely; 3.insert Tube Aging; 4.biopsy Tube Abrasion; 5.bending Section Abrasion; 6.wires And Helix Tube Abrasion; 7.light Guide Tube Aging And Wrinkle. |
| Solution | Replace CCD, Light Bundle, Insert Tube,biopsy Tube,aire&water Tube,bending Section,wires,helix Tube,light Guide Tube,all The Fstener Part,clamp And Rubber. |
| Packaging Details | Standard Package |
| Brand | Olympus |
|---|---|
| Model | CHF-P20Q |
| Fault | 1.Insert Tube Cracked; 2.Rubber Leakage; 3.Image With Black Point And Cracked; 4.Angulation Tight; 5.Biopsy Tube Aging |
| Solution | Replace Image Bundle; Insert Tube; Biopsy Tube; Bending Mesh And Wires; Coil Pipe; Rubber |
| Packaging Details | Standard Package |
| Brand | Olympus |
|---|---|
| Model | GIF-1TQ160 |
| Fault | 1.With Image, But CCD With Broken. 2.Light Bundle Broken Completely. 3.Insert Tube Abrasion. 4. No Biopsy Tube. 5. No Air&water Tube, No Water Supply Tube. 6. No Bending Section Assembly. 7. No Digital Tip. |
| Solution | Replace CCD, Digital Tip, Light Bundle, Insert Tube,biopsy Tube, Air&water Tube, Water Supply Tube,bending Section,wires,helix Tube And Rubber. |
| Packaging Details | Standard Package |
| Brand | Olympus |
|---|---|
| Model | GIF-H180J |
| Fault | 1.image With Shadow; 2.light Bundle Broken; 3.insert Tube With Bite Mark; 4.biopsy Tube Abrasion; 5.bending Section Serious Deformation; 6.wires And Helix Tube Abrasion; 7.light Guide Tube Aging And Wrinkle. |
| Solution | Replace CCD, Light Bundle, Insert Tube,biopsy Tube,aire&water Tube,bending Section,wires,helix Tube,light Guide Tube And Rubber. |
| Packaging Details | Standard Package |
| Brand | Olympus |
|---|---|
| Model | GIF-Q180 |
| Fault | 1.image Definition Not Enough, CCD Aging. 2.30% Light Bundle Broken. 3. Insert Tube Aging And Wrinkle. 4.Biopsy Tube Abrasion. 5. Bending Section Bited, Transformation. 6. Angle Not Enough, Wires And Helix Tube Abrasion. 7. Light Guide Tube Aging And |
| Solution | Replace CCD, Light Bundle,insert Tube, Biopsy Tube, Bending Section,helix Tube, Wires, Light Guide Tube, Pins And Rubber. |
| Packaging Details | Standard Package |