Bending Section Assembly For PENTAX EG-2990i Gastroscope
| Brand: | Pentax | Model: | EG-2990i |
| Condition: | Original / Compatible New | Series: | Bending Section Assy |
| MOQ: | 1 Piece | Package: | Carton / Standard Export Packing |
| Transportation: | DHL, FedEx, UPS, Etc. | In Stock: | Yes |
| Price: | Accept Negotiation | ||
| High Light: | PENTAX EG-2990i Bending Section Assembly,Bending Section Assembly Gastroscope |
||
Bending Section Assy For PENTAX EG-2990i Gastroscope
► Brief Description
The Pentax EG-2990i Bending Section assembly included bending section, mesh, angulation wire, coil pipe (helix tube).
► Features
-
Compatibility: Designed for Pentax colonoscopes or similar endoscope models.
-
Function: Replacement.
-
Material: Stainless Steel materials for durability and sterility.
-
Application: Used in gastrointestinal (GI) endoscopy, bronchoscopy, or hysteroscopy procedures.
► Replacement & Maintenance
- Professional Service Required: Bending section replacement is complex and typically performed by technicians.
- Replace if cracks, wear, or malfunction occurs.
- Use genuine PENTAX parts for optimal performance.
► Specification
| Brand | Pentax |
| Model | EG-2990i |
| Condition | Original & Compatible |
| Product | Bending section assy |
| MOQ | 1 set |
| Package | Carton / Standard Export Packing |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept Negotiation |
►FAQ
What clinical and mechanical signs indicate a failing bending section on the EG-2990i?
-
Loss of Articulation Range: Inability to achieve maximum up/down or right/left angulation angles specified by the manufacturer.
-
Slack or "Jumpy" Knobs: Excessive backlash or free play in the control body knobs before the distal tip begins to deflect.
-
Bumping or Catching: Grinding sensations or mechanical catching during rotation or bending.
-
Positive Leak Test Failure: Fluid invasion inside the insertion portion due to micro-tears or pinholes in the bending rubber sleeve.
How can facilities maximize the lifespan of the EG-2990i bending section?
-
Avoid excessive looping, sharp coiling, or forcing the insertion tube when resistance is met.
-
Always store the scope hanging vertically in a well-ventilated cabinet with the angulation locks fully released.
-
Strictly adhere to pre-cleaning, leak testing, and enzymatic washing protocols to prevent chemical degradation of the rubber sheath.
► More service
Spare parts for flexible endoscope: insert tube, wires,helix tube,coil pipe,C-cover,glass for CCD,glass for light bundle,objective lens for CCD,drive board for CCD,light guide tube, light bundle,forcep tube, bending section, rubber, air&water tube, CCD, light source, processor, monitor, etc.
► About Us
CareUtech is the global provider of medical equipment and medical equipment repair service, as well as offering spare parts. We focus on repair and repair training for monitor, Flexible & Rigid Endoscope, ultrasound, camera system, dynamical system and surgical instrument.
Shipping and packing
All products will be tested and sterilized for free, perfectly packed to ensure the safety of the goods, strictly in accordance with international export rules. We send to worldwide via EMS, DHL, FEDEX or other express, based on your choice.
► What we can do