| Brand | Olympus |
|---|---|
| Model | CYF V2 |
| Fault | Leakage |
| Solution | Replace The Insert Tube, Light Bundle, Biopsy Channel, Bending Section, Wire, Steel Mesh, Rubber |
| Packaging Details | Standard Package |
| Brand | Olympus |
|---|---|
| Model | GIF-XQ240 |
| Fault | Leakage. |
| Solution | Replace Light Guide Tube,NO.1 Button,wire,mesh,adjust Angle. |
| Packaging Details | Standard Package |
| Brand | Olympus |
|---|---|
| Model | GIF-Q150 |
| Fault | 1. With Image; 2. Light Bundlebreak Badly; 3. Insert Tubeaging; 4. Biopsy Tubeabrasion, Leakage Badly; 5. Angle Tied, Bendingsection, Wires And Helix Tube Abrasion; 6. Rubberwithout Glue. |
| Solution | Replace Light Bundle, Insert Tube, Biopsy Tube, Bending Section, Wires, Helixtube And Rubber. (No Warranty For CCD) |
| Packaging Details | Standard Package |
| Brand | Olympus |
|---|---|
| Model | A70940A |
| Fault | 1. Image Blur, Black Dots And Dark. 2. Fiber Not Light Enough. 3. Rod Lens Broken. 4. Objective Lens Broken And Dirty. |
| Solution | 1. Replace Rod Lens. 2. Replace Inner Tube. 3. Replace Outer Tube. 4. Replace Objective Lens Group. 5. Clean The Eyepiece. 6. Replace Fiber. 7. Clean And Install The Optical Path, Check The Image. 8. Seal With Endoscope And Test. |
| Packaging Details | Standard Package |
| Brand | Olympus |
|---|---|
| Model | A4674A |
| Fault | 1. Image Blur And Black Shadow. 2. Rod Lens Broken. 3. Outer Tube Bending And Transformation. |
| Solution | 1. Replace Rod Lens. 2. Replace Inner Tube. 3. Replace Outer Tube. 4. Replace Objective Lens Group. 5. Clean The Eyepiece. 6. Replace Fiber. 7. Clean And Install The Optical Path, Check The Image. 8. Seal With Endoscope And Test. |
| Packaging Details | Standard Package |
| Brand | Karl Storz |
|---|---|
| Model | 27005BA |
| Fault | 1. No Image. 2. Fiber Abrasion. 3. Rod Lens Broken And Cracked. 4. Objective Lens Broken And Dirty. 5. Eyepiece Cover Broken. |
| Solution | 1. Replace Rod Lens. 2. Replace Inner Tube. 3. Replace Outer Tube. 4. Replace Objective Lens Group. 5. Clean The Eyepiece. 6. Replace Fiber. 7. Replace Eyepiece Cover. 8. Clean And Install The Optical Path, Check The Image. 9. Seal With Endoscope A |
| Packaging Details | Standard Package |
| Brand | Philips |
|---|---|
| Model | L12-5 |
| Series | Crystal |
| Condition | Compatible & New |
| Brand Name | Careutech |
| Brand | OLYMPUS |
|---|---|
| Model | PCF-Q180 |
| Series | Body Cover |
| Condition | Pre-owned |
| Brand Name | Careutech |
| Brand | OLYMPUS |
|---|---|
| Model | TJF-160VR |
| Series | Body Cover |
| Condition | Pre-owned |
| Brand Name | Careutech |
| Brand | Olympus |
|---|---|
| Model | GIF-XQ240 |
| Series | Coil Pipe Assy |
| Condition | Compatible & New |
| Place of Origin | CHINA |