| Brand | Hitachi |
|---|---|
| Model | C41V1 |
| Fault | Lens Problem |
| Solution | Replace Lens |
| Packaging Details | Standard Package |
| Brand | GE |
|---|---|
| Model | RIC6-12-D |
| Fault | Lens Problem |
| Solution | Replace Lens,Clean Cable |
| Packaging Details | Standard Package |
| Brand | Olympus |
|---|---|
| Model | CF-240L |
| Fault | Leakage, Glass Of Light Bundle Blur, Rubber Leak, Angle Not Enough,image Fuzzle,objective Lens Scratch, |
| Solution | Replace Rubber, Objective Lens, C Cover. Adjust The Angle. |
| Packaging Details | Standard Package |
| Brand | OLYMPUS |
|---|---|
| Model | TJF-Q180V |
| Fault | 1. Image Ok; 2. Light Bundlestill Ok; 3. Insert Tubestill Ok; 4. Biopsy Tubewear; 5. Bendingsection, Wires And Helix Tube Wear; 6. Knob Leakage. |
| Solution | Suggest Toreplace Biopsy Tube, Bending Section, Wires, Helix Tube, Knob And Rubber. (Nowarranty For CCD) |
| Packaging Details | Standard Package |
| Brand | Philips |
|---|---|
| Model | S5-2 |
| Fault | Lens Problem, Cable Broken, Without Strain Relief |
| Solution | Replace Probe Lens, Repair Cable, Replace Strain Relief |
| Packaging Details | Standard Package |
| Brand | Philips |
|---|---|
| Model | L15-7io |
| Fault | Lens Problem |
| Solution | Replace Probe Lens |
| Packaging Details | Standard Package |
| Brand | Philips |
|---|---|
| Model | C5-1 |
| Fault | Lens Problem, Cable Broken, Without Strain Relief |
| Solution | Replace Probe Lens, Replace A New Cable, Replace Strain Relief |
| Packaging Details | Standard Package |
| Brand | Samsung |
|---|---|
| Model | P2-4AH |
| Fault | Lens Problem, Crystal Damage |
| Solution | Replace Probe Lens, Replace Crystal |
| Packaging Details | Standard Package |
| Brand | OLYMPUS |
|---|---|
| Model | GIF-Q150 |
| Fault | 1.with Image; 2.one Eye Of Light Bundle Broken; 3.insert Tube Little Aging; 4.biopsy Tube Abrasion; 5.bending Section Deformation; 6.wires And Helix Tube Abrasion; 7.light Guide Tube Aging And Wrinkle. |
| Solution | Replace Light Bundle ,insert Tube, Biopsy Tube,bending Section,wires,helix Tube,light Guide Tube And Rubber. |
| Packaging Details | Standard Package |
| Brand | Olympus |
|---|---|
| Model | LTF-160 |
| Fault | 1.with Image, But Big Risk For CCD After Leakage. 2. Light Bundle Broken Completely. 3. Insert Tube With Little Scratch. 4. Biopsy Tube Abrasion And Leakage. 5. Wires And Helix Tube Abrasion. 6. Grip Broken, Leakage. 7. All The Buttons Failure. 8. R |
| Solution | Replace CCD,light Bundle, Biopsy Tube, Wires,helix Tube,grip And Rubber, Repair All The Buttons. |
| Packaging Details | Standard Package |