| Brand | Olympus |
|---|---|
| Model | A4674A |
| Fault | 1. Image Blur And Black Shadow. 2. Rod Lens Broken. 3. Outer Tube Bending And Transformation. |
| Solution | 1. Replace Rod Lens. 2. Replace Inner Tube. 3. Replace Outer Tube. 4. Replace Objective Lens Group. 5. Clean The Eyepiece. 6. Replace Fiber. 7. Clean And Install The Optical Path, Check The Image. 8. Seal With Endoscope And Test. |
| Packaging Details | Standard Package |
| Brand | Karl Storz |
|---|---|
| Model | 27005BA |
| Fault | 1. No Image. 2. Fiber Abrasion. 3. Rod Lens Broken And Cracked. 4. Objective Lens Broken And Dirty. 5. Eyepiece Cover Broken. |
| Solution | 1. Replace Rod Lens. 2. Replace Inner Tube. 3. Replace Outer Tube. 4. Replace Objective Lens Group. 5. Clean The Eyepiece. 6. Replace Fiber. 7. Replace Eyepiece Cover. 8. Clean And Install The Optical Path, Check The Image. 9. Seal With Endoscope A |
| Packaging Details | Standard Package |
| Brand | OLYMPUS |
|---|---|
| Model | CF-H190L |
| Condition | Repaired |
| Brand Name | Careutech |
| Model Number | CF-H190L |
| Brand | GE |
|---|---|
| Model | RIC5-9-D |
| SN | 1870***** |
| Condition | Repaired |
| Brand Name | GE |
| Brand | GE |
|---|---|
| Model | 4D3C-L |
| Fault | 1.Probe Dome Abrasion & Leakage, 2. Dome Tube Damaged, 3. 4D Function Not Work, 4. Electric Motor Damaged. |
| Solution | Replace The Dome, Dome Tube; Repair Electric Motor |
| Packaging Details | Standard Package |
| Brand | GE |
|---|---|
| Model | 4C-RS |
| Fault | Lens Broken, Cable Broken, Crystal Bad |
| Solution | Replace Probe Head, Repair Cable |
| Packaging Details | Standard Package |
| Model | S5-2 |
|---|---|
| Fault | Lens Problem, Cable Broken, Without Strain Relief |
| Solution | Replace Probe Lens, Repair Cable, Replace Strain Relief |
| Packaging Details | Standard Package |
| Payment Terms | T/T, Western Union |
| Brand | Olympus |
|---|---|
| Model | LTF-160 |
| Fault | 1.with Image, But Big Risk For CCD After Leakage. 2. Light Bundle Broken Completely. 3. Insert Tube With Little Scratch. 4. Biopsy Tube Abrasion And Leakage. 5. Wires And Helix Tube Abrasion. 6. Grip Broken, Leakage. 7. All The Buttons Failure. 8. R |
| Solution | Replace CCD,light Bundle, Biopsy Tube, Wires,helix Tube,grip And Rubber, Repair All The Buttons. |
| Packaging Details | Standard Package |
| Brand | Olympus/ Pentax/ Fuji |
|---|---|
| Common Name | Air/Water Valve Tube (A/W Tube) |
| Condition | Compatible & New |
| Primary Function | Delivers Air For Insufflation And Water For Lens Cleaning. |
| Key Characteristic | Transparency (to Visually Confirm Patency And Flow). |
| Brand | OLYMPUS |
|---|---|
| Model | CF-Q160AL |
| Series | Insert Tube Boot |
| Condition | Compatible & New |
| MOQ | 1 Piece |