| Brand | GE |
|---|---|
| Model | RIC6-12-D |
| Fault | Lens Problem |
| Solution | Replace Lens,Clean Cable |
| Packaging Details | Standard Package |
| Brand | Olympus |
|---|---|
| Model | CF-240L |
| Fault | Leakage, Glass Of Light Bundle Blur, Rubber Leak, Angle Not Enough,image Fuzzle,objective Lens Scratch, |
| Solution | Replace Rubber, Objective Lens, C Cover. Adjust The Angle. |
| Packaging Details | Standard Package |
| Brand | OLYMPUS |
|---|---|
| Model | TJF-Q180V |
| Fault | 1. Image Ok; 2. Light Bundlestill Ok; 3. Insert Tubestill Ok; 4. Biopsy Tubewear; 5. Bendingsection, Wires And Helix Tube Wear; 6. Knob Leakage. |
| Solution | Suggest Toreplace Biopsy Tube, Bending Section, Wires, Helix Tube, Knob And Rubber. (Nowarranty For CCD) |
| Packaging Details | Standard Package |
| Brand | Philips |
|---|---|
| Model | L15-7io |
| Fault | Lens Problem |
| Solution | Replace Probe Lens |
| Packaging Details | Standard Package |
| Brand | STORZ |
|---|---|
| Model | 13820pks |
| Fault | 1.Rubber Leakage; 2.Wire Abrasion; 3. No Up Angle, Other Angle Lack Of |
| Solution | 1. Replace The Wires, Coil Pipe, Rubber; 2.Adjust Angle |
| Packaging Details | Standard Package |
| Brand | OLYMPUS |
|---|---|
| Model | GIF-Q150 |
| Fault | 1.with Image; 2.one Eye Of Light Bundle Broken; 3.insert Tube Little Aging; 4.biopsy Tube Abrasion; 5.bending Section Deformation; 6.wires And Helix Tube Abrasion; 7.light Guide Tube Aging And Wrinkle. |
| Solution | Replace Light Bundle ,insert Tube, Biopsy Tube,bending Section,wires,helix Tube,light Guide Tube And Rubber. |
| Packaging Details | Standard Package |
| Brand | Olympus |
|---|---|
| Model | GIF-H180J |
| Fault | 1.image With Shadow; 2.light Bundle Broken; 3.insert Tube With Bite Mark; 4.biopsy Tube Abrasion; 5.bending Section Serious Deformation; 6.wires And Helix Tube Abrasion; 7.light Guide Tube Aging And Wrinkle. |
| Solution | Replace CCD, Light Bundle, Insert Tube,biopsy Tube,aire&water Tube,bending Section,wires,helix Tube,light Guide Tube And Rubber. |
| Packaging Details | Standard Package |
| Brand | Olympus |
|---|---|
| Model | GIF-H170 |
| Fault | 1. The Top Left And Middle Right Side With Blur Image, Objective Lens Broken. 2. 20% Light Bundle Broken, The Small Lens Turned Yellow. 3. Insert Tube Yellow And Wrinkles. 4. The Biopsy Tube Abrasion. 5. The Wire And Helix Tube Abrasion. 6. Light Gu |
| Solution | Replace Objective Lens, Light Bundle, Small Lens, Insert Tube, Biopsy Tube, Wires, Helix Tube, Light Guide Tube And Rubber. |
| Packaging Details | Standard Package |
| Brand | Olympus |
|---|---|
| Model | GIF-1TQ160 |
| Fault | 1.With Image, But CCD With Broken. 2.Light Bundle Broken Completely. 3.Insert Tube Abrasion. 4. No Biopsy Tube. 5. No Air&water Tube, No Water Supply Tube. 6. No Bending Section Assembly. 7. No Digital Tip. |
| Solution | Replace CCD, Digital Tip, Light Bundle, Insert Tube,biopsy Tube, Air&water Tube, Water Supply Tube,bending Section,wires,helix Tube And Rubber. |
| Packaging Details | Standard Package |
| Brand | Olympus |
|---|---|
| Model | CF-Q160AL |
| Fault | 1.No Image, CCD Broken; 2.image Broken Completely; 3.insert Tube Aging; 4.biopsy Tube Abrasion; 5.bending Section Abrasion; 6.wires And Helix Tube Abrasion; 7.light Guide Tube Aging And Wrinkle. |
| Solution | Replace CCD, Light Bundle, Insert Tube,biopsy Tube,aire&water Tube,bending Section,wires,helix Tube,light Guide Tube,all The Fstener Part,clamp And Rubber. |
| Packaging Details | Standard Package |