| Brand | Olympus |
|---|---|
| Model | GIF-H180J |
| Fault | 1.image With Shadow; 2.light Bundle Broken; 3.insert Tube With Bite Mark; 4.biopsy Tube Abrasion; 5.bending Section Serious Deformation; 6.wires And Helix Tube Abrasion; 7.light Guide Tube Aging And Wrinkle. |
| Solution | Replace CCD, Light Bundle, Insert Tube,biopsy Tube,aire&water Tube,bending Section,wires,helix Tube,light Guide Tube And Rubber. |
| Packaging Details | Standard Package |
| Brand | Olympus |
|---|---|
| Model | BF-XP160F |
| Fault | 1. Image Degumming, Serious Color, CCD Aging, A Few Black And Gray Spots; 2. 20% Of The Light Bundle Is Broken; 3. Insert Tube Aging Slightly; 4. Biopsy Tube Wear, Not Smooth; 5. Bending Section, Steel Wire, Screw Tube Wear; |
| Solution | Replace CCD, Image Beam, Beam, Insert Tube, Pliers Tube, Snake Bone, Steel Wire, Spiral Tube, Rubber. |
| Packaging Details | Standard Package |
| Brand | R Wolf |
|---|---|
| Model | 7326071 |
| Fault | The Image Has Spots,image Bundle Aging,light Bundle Broken;Insert Tube Aging;Biopsy Channel Worn And Leakage;Bending Section,wire And Helix Tube Were Worn |
| Solution | Replace The Light Bundle,image Bundle,rubber,biopsy Channel,helix Tube,wire. |
| Packaging Details | Standard Package |
| Brand | LINVATEC |
|---|---|
| Model | HD 4300 |
| Fault | Image With Black Shadow; Eyepiece With Scratches, Inner Optical Parts Broken. |
| Solution | Replace Objective Lens, Inner Optical Parts, Clean And Adjust Optical System, |
| Packaging Details | Standard Package |
| Brand | Olympus |
|---|---|
| Model | SPL-T |
| Ultrasonic Crystal | Damaged |
| Fault | No Ultrasonic Energy Output |
| Solution | Replace The Ultrasonic Crystal |
| Brand | Philips |
|---|---|
| Model | EPlQ/X5-1 |
| Fault | 2D Image Abnormal |
| Solution | Replace Scanhead |
| Packaging Details | Standard Package |
| Brand | Samsung |
|---|---|
| Model | 3D4-9 |
| Fault | Scanhead Broken |
| Solution | Replace Scanhead |
| Packaging Details | Standard Package |
| Brand | BK Medical |
|---|---|
| Model | 9096 |
| Fault | All The Outer Skin Of The Cable Is Seriously Damaged |
| Solution | Replace The Outer Skin Of The Cable |
| Packaging Details | Standard Package |
| Brand | Sonoscape |
|---|---|
| Model | L743 |
| Fault | Probe Head Broken |
| Solution | Replace Probe Head.(including Crystal And Upper Housing) |
| Packaging Details | Standard Package |
| Brand | STORZ |
|---|---|
| Model | H3-ZA |
| Fault | Image Streaks Frequently,cable Loose Contact And Aged |
| Solution | Replace Cable Kit |
| Packaging Details | Standard Package |