| Brand | Olympus |
|---|---|
| Model | TJF-160VR |
| Fault | 1.No Image, CCD Broken. 2. Light Bundle Broken Completely. 3. Insert Tube Aging And Wrinkle. 4. Biopsy Tube Broken. 5. Wires And Helix Tube Broken. 6. Clamp Wires Broken. 7. Operation Part Broken, No Angle. 8. Grip Broken. 9. The Scope Be Separated |
| Solution | Replace Digital Parts,CCD,light Bundle,insert Tube, Biopsy Tube,air&water Tube, Bending Section, Wires,helix Tube, Clamp Wires,grip,operation Part And Rubber. |
| Packaging Details | Standard Package |
| Brand | Olympus |
|---|---|
| Model | LTF-160 |
| Fault | 1.with Image, But Big Risk For CCD After Leakage. 2. Light Bundle Broken Completely. 3. Insert Tube With Little Scratch. 4. Biopsy Tube Abrasion And Leakage. 5. Wires And Helix Tube Abrasion. 6. Grip Broken, Leakage. 7. All The Buttons Failure. 8. R |
| Solution | Replace CCD,light Bundle, Biopsy Tube, Wires,helix Tube,grip And Rubber, Repair All The Buttons. |
| Packaging Details | Standard Package |
| Brand | Olympus |
|---|---|
| Model | GIF-H180J |
| Fault | 1.image With Shadow; 2.light Bundle Broken; 3.insert Tube With Bite Mark; 4.biopsy Tube Abrasion; 5.bending Section Serious Deformation; 6.wires And Helix Tube Abrasion; 7.light Guide Tube Aging And Wrinkle. |
| Solution | Replace CCD, Light Bundle, Insert Tube,biopsy Tube,aire&water Tube,bending Section,wires,helix Tube,light Guide Tube And Rubber. |
| Packaging Details | Standard Package |
| Brand | Olympus |
|---|---|
| Model | CHF-P20Q |
| Fault | 1.Insert Tube Cracked; 2.Rubber Leakage; 3.Image With Black Point And Cracked; 4.Angulation Tight; 5.Biopsy Tube Aging |
| Solution | Replace Image Bundle; Insert Tube; Biopsy Tube; Bending Mesh And Wires; Coil Pipe; Rubber |
| Packaging Details | Standard Package |
| Brand | Olympus |
|---|---|
| Model | BF-XP160F |
| Fault | 1. Image Degumming, Serious Color, CCD Aging, A Few Black And Gray Spots; 2. 20% Of The Light Bundle Is Broken; 3. Insert Tube Aging Slightly; 4. Biopsy Tube Wear, Not Smooth; 5. Bending Section, Steel Wire, Screw Tube Wear; |
| Solution | Replace CCD, Image Beam, Beam, Insert Tube, Pliers Tube, Snake Bone, Steel Wire, Spiral Tube, Rubber. |
| Packaging Details | Standard Package |
| Brand | Olympus |
|---|---|
| Model | ENF-GP |
| Fault | 1. Image With Black Point And Image Bundle Broken 2. Light Bundle Aged 3. Insert Tube Aging And Wrinkle 4. Bending Section Deformation 5. Angle With Not Enough 6. Rubber Abrasion |
| Solution | Replace Image Bundle; Light Bundle; Insert Tube; Wires; Helix Tube; Bending Section; Rubber |
| Packaging Details | Standard Package |
| Brand | KARL STORZ |
|---|---|
| Model | 11278A1 |
| Fault | 1) Image Spotted With Partially Black Point, Image Bundle Aged 2) Light Bundle Partially Wire Broken 3) Insert Tube Aged 4) Biopsy Tube Abrasion And Leakage 5) Wires And Coil Pipe Abrasion |
| Solution | Replace HD Image Bundle, Light Bundle, Insert Tube, Wires, Coil Pipe And Rubber. |
| Packaging Details | Standard Package |
| Brand | Insighters |
|---|---|
| Model | IS3-F |
| Fault | 1. Image Blank Screen; 2. Insert Tube Abrasion 3. Bending Section Transformation; 4. Distal Head Transformation; |
| Solution | Replace CCD, Insert Tube, Bending Section, Rubber |
| Packaging Details | Standard Package |
| Brand | R Wolf |
|---|---|
| Model | 7326071 |
| Fault | The Image Has Spots,image Bundle Aging,light Bundle Broken;Insert Tube Aging;Biopsy Channel Worn And Leakage;Bending Section,wire And Helix Tube Were Worn |
| Solution | Replace The Light Bundle,image Bundle,rubber,biopsy Channel,helix Tube,wire. |
| Packaging Details | Standard Package |
| Brand | Olympus |
|---|---|
| Model | GIF-Q150 |
| Fault | 1. With Image; 2. Light Bundlebreak Badly; 3. Insert Tubeaging; 4. Biopsy Tubeabrasion, Leakage Badly; 5. Angle Tied, Bendingsection, Wires And Helix Tube Abrasion; 6. Rubberwithout Glue. |
| Solution | Replace Light Bundle, Insert Tube, Biopsy Tube, Bending Section, Wires, Helixtube And Rubber. (No Warranty For CCD) |
| Packaging Details | Standard Package |